Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 5 de 5
Filter
Add filters








Year range
1.
Journal of Korean Neurosurgical Society ; : 503-508, 2018.
Article in English | WPRIM | ID: wpr-765269

ABSTRACT

OBJECTIVE: Anterior odontoid screw fixation is a safe and effective method for the treatment of odontoid fractures. The surgical technique is recommended for perforation of the apical cortex of the dens by the lag screw. However, overpenetration of the apical cortex may lead to potentially serious complications such as damages of adjacent vascular and neural structures. The purpose of this study was to assess the role of three-dimensional computed tomography (CT) scan to evaluate the safe margin beyond dens tip to ventral dura for anterior odontoid screw fixation. METHODS: We retrospectively analyzed the three-dimensional CT scans of the cervical spines in 55 consecutive patients at our trauma center. The patients included 38 males and 17 females aged between 22 and 73 years (mean age±standard deviation, 45.8±14.2 years). Using sagittal images of 3-dimensional CT scan, the safe margins beyond dens tip to ventral dura as well as the appropriate screw length were measured. RESULTS: The mean width of the apical dens tip was 9.6±1.1 mm. The mean lengths from the screw entry point to the apical dens tip and posterior end of dens tip were 39.2±2.6 mm and 36.6±2.4 mm. The safe margin beyond apical dens tip to ventral dura was 7.7±1.7 mm. However, the safe margin beyond the posterior end of dens tip to ventral dura was decreased to 2.1±3.2 mm, which was statistically significant (p < 0.01). There were no significant differences of safe margins beyond dens tip to ventral dura with patient gender and age. CONCLUSION: Extension by several millimeters beyond the dens tip is safe, if the trajectory of anterior odontoid screw is targeted at the apical dens tip. However, if the trajectory of the screw is targeted to the posterior end of dens tip, extension beyond dens tip may lead to damage immediately adjacent to the vental dura mater.


Subject(s)
Female , Humans , Male , Bone Screws , Dura Mater , Methods , Odontoid Process , Retrospective Studies , Spinal Fractures , Spine , Tomography, X-Ray Computed , Trauma Centers
2.
Journal of Korean Neurosurgical Society ; : 503-508, 2018.
Article in English | WPRIM | ID: wpr-788699

ABSTRACT

OBJECTIVE: Anterior odontoid screw fixation is a safe and effective method for the treatment of odontoid fractures. The surgical technique is recommended for perforation of the apical cortex of the dens by the lag screw. However, overpenetration of the apical cortex may lead to potentially serious complications such as damages of adjacent vascular and neural structures. The purpose of this study was to assess the role of three-dimensional computed tomography (CT) scan to evaluate the safe margin beyond dens tip to ventral dura for anterior odontoid screw fixation.METHODS: We retrospectively analyzed the three-dimensional CT scans of the cervical spines in 55 consecutive patients at our trauma center. The patients included 38 males and 17 females aged between 22 and 73 years (mean age±standard deviation, 45.8±14.2 years). Using sagittal images of 3-dimensional CT scan, the safe margins beyond dens tip to ventral dura as well as the appropriate screw length were measured.RESULTS: The mean width of the apical dens tip was 9.6±1.1 mm. The mean lengths from the screw entry point to the apical dens tip and posterior end of dens tip were 39.2±2.6 mm and 36.6±2.4 mm. The safe margin beyond apical dens tip to ventral dura was 7.7±1.7 mm. However, the safe margin beyond the posterior end of dens tip to ventral dura was decreased to 2.1±3.2 mm, which was statistically significant (p < 0.01). There were no significant differences of safe margins beyond dens tip to ventral dura with patient gender and age.CONCLUSION: Extension by several millimeters beyond the dens tip is safe, if the trajectory of anterior odontoid screw is targeted at the apical dens tip. However, if the trajectory of the screw is targeted to the posterior end of dens tip, extension beyond dens tip may lead to damage immediately adjacent to the vental dura mater.


Subject(s)
Female , Humans , Male , Bone Screws , Dura Mater , Methods , Odontoid Process , Retrospective Studies , Spinal Fractures , Spine , Tomography, X-Ray Computed , Trauma Centers
3.
Journal of the Korean Neurological Association ; : 63-64, 2010.
Article in Korean | WPRIM | ID: wpr-95203

ABSTRACT

No abstract available.


Subject(s)
Abdominal Wall , Herpes Zoster
4.
Journal of the Korean Surgical Society ; : 354-366, 1993.
Article in Korean | WPRIM | ID: wpr-51745

ABSTRACT

No abstract available.

5.
Journal of the Korean Surgical Society ; : 722-728, 1992.
Article in Korean | WPRIM | ID: wpr-43128

ABSTRACT

No abstract available.


Subject(s)
Appendix , Pseudomyxoma Peritonei
SELECTION OF CITATIONS
SEARCH DETAIL